source: MondoRescue/trunk/mindi/install.sh @ 461

Last change on this file since 461 was 461, checked in by bcornec, 14 years ago

merge -r447:460 $SVN_M/branches/stable

  • Property svn:keywords set to Id
File size: 4.5 KB
RevLine 
[181]1#!/bin/bash
[1]2
3if [ ! -f "mindi" ] ; then
4    echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
5    exit 1
6fi
[181]7
[186]8if [ "_$PREFIX" != "_" ]; then
[236]9    local=$PREFIX
[181]10    if [ -f /usr/local/sbin/mindi ]; then
11        echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
12    fi
[236]13    conf=$CONFDIR/mindi
[186]14    echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
[181]15else
16    local=/usr/local
17    if [ -f /usr/sbin/mindi ]; then
18        echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
19    fi
20    conf=$local/etc/mindi
[186]21    echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
[181]22fi
23
[1]24if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
25    local=/ramdisk/usr
26    export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
27fi
28
[238]29MINDIVER=`cat VERSION`
[244]30MINDIREV=`cat REVISION`
31echo "mindi ${MINDIVER}-r${MINDIREV} will be installed under $local"
[181]32
[250]33DOCDIR=$local/share/doc/mindi-$MINDIVER
34MANDIR=$local/share/man/man8
[244]35
[309]36ARCH=`/bin/arch`
37echo $ARCH | grep -x "i[0-9]86" &> /dev/null && ARCH=i386 && locallib=$local/lib
38# For the moment, we don't build specific x86_64 busybox binaries
39echo $ARCH | grep -x "x86_64" &> /dev/null && ARCH=i386 && locallib=$local/lib64
40export ARCH
41
[181]42echo "Creating target directories ..."
[461]43install -m 755 -d $conf $conf/deplist.d $locallib/mindi $MANDIR $local/sbin $DOCDIR
[1]44
[181]45echo "Copying files ..."
[309]46install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $locallib/mindi
[238]47install -m 644 deplist.txt $conf
[461]48install -m 644 distributions/conf/deplist.d/* $conf/deplist.d
49install -m 755 distributions/conf/mindi.conf $conf
[236]50
[317]51cp -af rootfs aux-tools $locallib/mindi
[309]52chmod 755 $locallib/mindi/rootfs/bin/*
53chmod 755 $locallib/mindi/rootfs/sbin/*
54chmod 755 $locallib/mindi/aux-tools/sbin/*
[461]55chmod 755 $conf/mindi.conf
[1]56
[181]57if [ "$RPMBUILDMINDI" = "true" ]; then
[244]58    sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
[181]59else
[244]60    sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
[181]61fi
62chmod 755 $local/sbin/mindi
[238]63install -m 755 analyze-my-lvm parted2fdisk.pl $local/sbin
[181]64
[250]65install -m 644 mindi.8 $MANDIR
[317]66install -m 644 ChangeLog COPYING README README.busybox README.ia64 README.pxe TODO INSTALL svn.log $DOCDIR
[181]67
[236]68# Managing busybox
[309]69if [ -f $locallib/mindi/rootfs/bin/busybox-$ARCH ]; then
[181]70        echo "Installing busybox ..."
[309]71        install -s -m 755 $locallib/mindi/rootfs/bin/busybox-$ARCH $locallib/mindi/rootfs/bin/busybox
[181]72else
73        echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
74fi
[1]75if [ "$ARCH" = "i386" ] ; then
[309]76    if [ -f $locallib/mindi/rootfs/bin/busybox-$ARCH.net ]; then
[181]77        echo "Installing busybox.net ..."
[309]78        install -s -m 755 $locallib/mindi/rootfs/bin/busybox-$ARCH.net $locallib/mindi/rootfs/bin/busybox.net
[181]79    else
80        echo "WARNING: no busybox.net found, mindi will not work on this arch ($ARCH) with network"
81    fi
[1]82fi
[236]83# Remove left busybox
[309]84rm -f $locallib/mindi/rootfs/bin/busybox-*
[181]85
[236]86# Managing parted2fdisk
[1]87if [ "$ARCH" = "ia64" ] ; then
[236]88    (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
[309]89    make -f Makefile.parted2fdisk DEST=$locallib/mindi install
90    if [ -f $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
[181]91        echo "Installing parted2fdisk ..."
[309]92        install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $locallib/mindi/rootfs/sbin/parted2fdisk
93        install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
[181]94    else
95        echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
96    fi
[1]97else
[236]98    # FHS requires fdisk under /sbin
99    (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
[181]100    echo "Symlinking fdisk to parted2fdisk"
[309]101    ( cd $locallib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
[1]102fi
[236]103# Remove left parted2fdisk
[309]104rm -f $locallib/mindi/rootfs/sbin/parted2fdisk-*
[181]105
[238]106if [ "$RPMBUILDMINDI" != "true" ]; then
[309]107    chown -R root:root $locallib/mindi $conf $DOCDIR
[250]108    chown root:root $local/sbin/mindi $MANDIR/mindi.8 $local/sbin/analyze-my-lvm $local/sbin/parted2fdisk.pl
[238]109    if [ "$ARCH" = "ia64" ] ; then
110        chown root:root $local/sbin/parted2fdisk
111    fi
112fi
113
[461]114# Special case for SuSE family wher doc is put elsewhere in the RPM
115if [ _"$dfam" != _"suse" ] then;
116    rm -rf $DOCDIR
117fi
118
[1]119exit 0
Note: See TracBrowser for help on using the repository browser.