| 829 | == Q47/ mondorestore is not finding my disks on my HP ProLiant server == |
| 830 | |
| 831 | This is probably due to the fact your using the old cciss driver loaded first, whereas you would need the more recent hpsa one. |
| 832 | You can refer to this matrix to understand the support of SmartArray Controllers on some Linux distributions, Cf: http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us&prodSeriesId=5193414&objectID=c03358230 |
| 833 | Reproduced here for more clarity (TBD) |
| 834 | Also refer to the documentation available on HP Web site at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c02677069/c02677069.pdf |
| 835 | |
| 836 | In !MondoRescue, one way to solve this is to boot your already nade media using the option denymods=cciss |
| 837 | Also at restore time, you can force the order of the loaded modules at restore time by using FORCE_MODS="hpsa cciss" in order to have hpsa loaded first and handling newest configuration; Note that SLES 11 SP1 provided a preliminary hpsa version and would probably require you to download the HP kiso instead of this one to have a working version. |