Ticket Owner Reporter Resolution Summary
#242 Bruno Cornec mitsant invalid preciso de sistema para backup
Description

ok

#243 Bruno Cornec amaura fixed Includes in modprobe.conf
Description

Hello,

I had a problem with mondo rescue and a machine using powerpath (multipath software from EMC). Indeed PowerPath added a new file (/etc/modprobe.conf.pp) and an include referencing it in modprobe.conf (include modprobe.conf.pp). I have also seen this include with IBM Rdac driver.

My problem was the ext3 module not loaded with the mindi CD. And it was solved by adding the file in /etc/mindi/deplist.txt.

Would it be possible to make mindi parse the modprobe.conf file for any include and then include the files automatically in the Bootable image ?

#245 Bruno Cornec lejav fixed LVM Logical Volumes size is rounded to GB
Description

A logical volume whose size is for instance 1.5 GB

is restored to 1 GB by mondo.

OS = RedHat 4 / RedHat 5 The problem comes from the function GetValueFromField in /usr/lib/mindi/analyze-my-lvm

which gives the size by awk '{printf "%d",...}' from the line LV Size given by lvdisplay.

For my example, LV Size = 1.50 GB, and awk '{printf "%d","1.50"}' prints '1' A solution is to change 'lvdisplay' by 'lvdisplay --units m' ; but i don't

know if this option is supported on every platform.

Not sure that this is a bug or a limitation.

Batch Modify
Note: See TracBatchModify for help on using batch modify.
Note: See TracQuery for help on using queries.