source: branches/3.0/mindi/install.sh @ 3173

Last change on this file since 3173 was 3173, checked in by Bruno Cornec, 7 years ago
  • Use 2 README files as embedded doc for restore boot, with function keys
  • Improve #628 by adding a comment in order to connect external disks after the boot.
  • Improve also boot menu visibility.
  • Property svn:keywords set to Id
File size: 3.7 KB
Line 
1#!/bin/bash
2#
3# $Id: install.sh 3173 2013-07-29 07:08:58Z bruno $
4#
5
6if [ ! -f "mindi" ] ; then
7    echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
8    exit 1
9fi
10
11if [ "_$PREFIX" != "_" ]; then
12    local=${HEAD}$PREFIX
13    sublocal=$PREFIX
14    if [ "_$CONFDIR" != "_" ]; then
15        conf=${HEAD}$CONFDIR/mindi
16        subconf=$CONFDIR/mindi
17    else
18        echo "CONFDIR should be defined if PREFIX is defined"
19        exit -1
20    fi
21else
22    local=/usr/local
23    sublocal=$local
24    if [ -f /usr/sbin/mindi ]; then
25        echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
26    fi
27    conf=$local/etc/mindi
28    subconf=$conf
29    echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
30fi
31
32if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
33    local=/ramdisk/usr
34    sublocal=$local
35    conf=/ramdisk/etc
36    subconf=$conf
37    export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
38fi
39
40MINDIVER=PBVER
41MINDIREV=PBREV
42VERSTR=${MINDIVER}-r${MINDIREV}
43ARCH=`/bin/uname -m`
44echo "mindi $VERSTR will be installed under $local"
45
46if [ _"$CACHEDIR" = _"" ]; then
47    CACHEDIR=$local/var/cache/mindi
48else
49    CACHEDIR=${HEAD}$CACHEDIR
50fi
51if [ _"$MANDIR" = _"" ]; then
52    MANDIR=$local/share/man/man8
53else
54    MANDIR=${HEAD}$MANDIR/man8
55fi
56if [ _"$DOCDIR" = _"" ]; then
57    DOCDIR=$local/share/doc/mindi-$MINDIVER
58else
59    DOCDIR=${HEAD}$DOCDIR/mindi-$MINDIVER
60fi
61if [ _"$LIBDIR" = _"" ]; then
62    echo $ARCH | grep -E '^i[0-9]86$' &> /dev/null && ARCH=i386 && locallib=$local/lib
63    echo $ARCH | grep -E '^x86_64$' &> /dev/null && locallib=$local/lib64
64    echo $ARCH | grep -E '^ia64$' &> /dev/null && locallib=$local/lib
65    sublocallib="$locallib/mindi"
66else
67    locallib=${HEAD}$LIBDIR
68    sublocallib="$LIBDIR/mindi"
69fi
70
71echo "Creating target directories ..."
72install -m 755 -d $conf $locallib/mindi $MANDIR $local/sbin $CACHEDIR $conf/deplist.d
73
74echo "Copying files ..."
75cp -af rootfs $locallib/mindi
76chmod 755 $locallib/mindi/rootfs/sbin/*
77install -m 755 analyze-my-lvm $locallib/mindi
78install -m 644 msg-txt dev.tgz $locallib/mindi
79install -m 644 deplist.txt mindi.conf README.bootparam README.pxe $conf
80for f in deplist.d/*.conf; do
81    install -m 644 $f $conf/deplist.d
82done
83
84# Substitute variables for mindi
85sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$sublocal~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$subconf~" -e "s~^MINDI_LIB=LLL~MINDI_LIB=$sublocallib~" mindi > $local/sbin/mindi
86chmod 755 $local/sbin/mindi
87install -m 644 mindi.8 $MANDIR
88
89# Manage perl script man pages
90for s in mindi-bkphw mindi-get-perl-modules parted2fdisk.pl; do
91    install -m 755 $s $local/sbin
92    pod2man -c "$s a MondoRescue tool" --section=8 --release="$VERSTR" $local/sbin/$s > $s.8
93    install -m 644 $s.8 $MANDIR
94    # Generate the list of perl modules needed at restore time for mindi
95    cat > $conf/perl-scripts << EOF
96$sublocal/sbin/$s
97EOF
98done
99(cd $MANDIR ; ln -s parted2fdisk.pl.8 parted2fdisk.9)
100
101if [ "_$PREFIX" = "_" ] && [ ! -f $locallib/mindi/rootfs/bin/busybox ]; then
102    echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
103fi
104
105# Managing parted2fdisk
106if [ "$ARCH" = "ia64" ] ; then
107    (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
108    install -s -m 755 $local/sbin/parted2fdisk.pl $locallib/mindi/rootfs/sbin/parted2fdisk
109else
110    # FHS requires fdisk under /sbin
111    (cd $local/sbin && ln -sf ../../sbin/fdisk parted2fdisk)
112    echo "Symlinking fdisk to parted2fdisk"
113    ( cd $locallib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
114fi
115
116if [ "$PKGBUILDMINDI" != "true" ]; then
117    chown -R root:root $locallib/mindi $conf # $DOCDIR
118    chown root:root $local/sbin/mindi $MANDIR/mindi.8 $locallib/mindi/analyze-my-lvm $local/sbin/parted2fdisk.pl
119    if [ "$ARCH" = "ia64" ] ; then
120        chown root:root $local/sbin/parted2fdisk
121    fi
122fi
123
124exit 0
Note: See TracBrowser for help on using the repository browser.