source: MondoRescue/branches/2.05/mindi/install.sh@ 242

Last change on this file since 242 was 242, checked in by bcornec, 18 years ago

sles9 fixes for RPM build

  • Property svn:keywords set to Id
File size: 4.1 KB
RevLine 
[179]1#!/bin/bash
[1]2
3if [ ! -f "mindi" ] ; then
4 echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
5 exit 1
6fi
[179]7
[184]8if [ "_$PREFIX" != "_" ]; then
[235]9 local=$PREFIX
[179]10 if [ -f /usr/local/sbin/mindi ]; then
11 echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
12 fi
[235]13 conf=$CONFDIR/mindi
[185]14 echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
[179]15else
16 local=/usr/local
17 if [ -f /usr/sbin/mindi ]; then
18 echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
19 fi
20 conf=$local/etc/mindi
[185]21 echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
[179]22fi
23
[1]24if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
25 local=/ramdisk/usr
26 export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
27fi
28
[237]29MINDIVER=`cat VERSION`
30echo "mindi $MINDIVER will be installed under $local"
[179]31
[241]32if [ "_$DOCDIR" = "_" ]; then
33 DOCDIR=$local/share/doc/mindi-$MINDIVER
34fi
35
[179]36echo "Creating target directories ..."
[241]37install -m 755 -d $conf $local/lib/mindi $local/share/man/man8 $local/sbin $DOCDIR
[1]38
[179]39echo "Copying files ..."
[237]40install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $local/lib/mindi
41install -m 644 deplist.txt $conf
[235]42
[237]43cp -af rootfs aux-tools Mindi $local/lib/mindi
[179]44chmod 755 $local/lib/mindi/rootfs/bin/*
45chmod 755 $local/lib/mindi/rootfs/sbin/*
46chmod 755 $local/lib/mindi/aux-tools/sbin/*
[1]47
[179]48if [ "$RPMBUILDMINDI" = "true" ]; then
49 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" mindi > $local/sbin/mindi
50else
51 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" mindi > $local/sbin/mindi
52fi
53chmod 755 $local/sbin/mindi
[237]54install -m 755 analyze-my-lvm parted2fdisk.pl $local/sbin
[179]55
[237]56install -m 644 mindi.8 $local/share/man/man8
[241]57install -m 644 CHANGES COPYING README README.busybox README.ia64 README.pxe TODO INSTALL $DOCDIR
[179]58
[1]59ARCH=`/bin/arch`
60echo $ARCH | grep -x "i[0-9]86" &> /dev/null && ARCH=i386
[235]61# For the moment, we don't build specific x86_64 busybox binaries
62echo $ARCH | grep -x "x86_64" &> /dev/null && ARCH=i386
[1]63export ARCH
[179]64
[235]65# Managing busybox
[179]66if [ -f $local/lib/mindi/rootfs/bin/busybox-$ARCH ]; then
67 echo "Installing busybox ..."
[237]68 install -s -m 755 $local/lib/mindi/rootfs/bin/busybox-$ARCH $local/lib/mindi/rootfs/bin/busybox
[179]69else
70 echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
71fi
[1]72if [ "$ARCH" = "i386" ] ; then
[179]73 if [ -f $local/lib/mindi/rootfs/bin/busybox-$ARCH.net ]; then
74 echo "Installing busybox.net ..."
[237]75 install -s -m 755 $local/lib/mindi/rootfs/bin/busybox-$ARCH.net $local/lib/mindi/rootfs/bin/busybox.net
[179]76 else
77 echo "WARNING: no busybox.net found, mindi will not work on this arch ($ARCH) with network"
78 fi
[1]79fi
[235]80# Remove left busybox
81rm -f $local/lib/mindi/rootfs/bin/busybox-*
[179]82
[235]83# Managing parted2fdisk
[1]84if [ "$ARCH" = "ia64" ] ; then
[235]85 (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
[179]86 make -f Makefile.parted2fdisk DEST=$local/lib/mindi install
87 if [ -f $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
88 echo "Installing parted2fdisk ..."
[237]89 install -s -m 755 $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/lib/mindi/rootfs/sbin/parted2fdisk
90 install -s -m 755 $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
[179]91 else
92 echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
93 fi
[1]94else
[235]95 # FHS requires fdisk under /sbin
96 (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
[179]97 echo "Symlinking fdisk to parted2fdisk"
98 ( cd $local/lib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
[1]99fi
[235]100# Remove left parted2fdisk
101rm -f $local/lib/mindi/rootfs/sbin/parted2fdisk-*
[179]102
[237]103if [ "$RPMBUILDMINDI" != "true" ]; then
[241]104 chown -R root:root $local/lib/mindi $conf/mindi $conf $DOCDIR
[237]105 chown root:root $local/sbin/mindi $local/share/man/man8/mindi.8 $local/sbin/analyze-my-lvm $local/sbin/parted2fdisk.pl
106 if [ "$ARCH" = "ia64" ] ; then
107 chown root:root $local/sbin/parted2fdisk
108 fi
109fi
110
[1]111exit 0
Note: See TracBrowser for help on using the repository browser.