1 | #!/bin/bash
|
---|
2 |
|
---|
3 | if [ ! -f "mindi" ] ; then
|
---|
4 | echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
|
---|
5 | exit 1
|
---|
6 | fi
|
---|
7 |
|
---|
8 | if [ "_$PREFIX" != "_" ]; then
|
---|
9 | local=$PREFIX
|
---|
10 | if [ -f /usr/local/sbin/mindi ]; then
|
---|
11 | echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
|
---|
12 | fi
|
---|
13 | conf=$CONFDIR/mindi
|
---|
14 | echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
|
---|
15 | else
|
---|
16 | local=/usr/local
|
---|
17 | if [ -f /usr/sbin/mindi ]; then
|
---|
18 | echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
|
---|
19 | fi
|
---|
20 | conf=$local/etc/mindi
|
---|
21 | echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
|
---|
22 | fi
|
---|
23 |
|
---|
24 | if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
|
---|
25 | local=/ramdisk/usr
|
---|
26 | export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
|
---|
27 | fi
|
---|
28 |
|
---|
29 | MINDIVER=`cat VERSION`
|
---|
30 | echo "mindi $MINDIVER will be installed under $local"
|
---|
31 |
|
---|
32 | echo "Creating target directories ..."
|
---|
33 | install -m 755 -d $conf $local/lib/mindi $local/share/man/man8 $local/sbin $local/share/doc/mindi-$MINDIVER
|
---|
34 |
|
---|
35 | echo "Copying files ..."
|
---|
36 | install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $local/lib/mindi
|
---|
37 | install -m 644 deplist.txt $conf
|
---|
38 |
|
---|
39 | cp -af rootfs aux-tools Mindi $local/lib/mindi
|
---|
40 | chmod 755 $local/lib/mindi/rootfs/bin/*
|
---|
41 | chmod 755 $local/lib/mindi/rootfs/sbin/*
|
---|
42 | chmod 755 $local/lib/mindi/aux-tools/sbin/*
|
---|
43 |
|
---|
44 | if [ "$RPMBUILDMINDI" = "true" ]; then
|
---|
45 | sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" mindi > $local/sbin/mindi
|
---|
46 | else
|
---|
47 | sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" mindi > $local/sbin/mindi
|
---|
48 | fi
|
---|
49 | chmod 755 $local/sbin/mindi
|
---|
50 | install -m 755 analyze-my-lvm parted2fdisk.pl $local/sbin
|
---|
51 |
|
---|
52 | install -m 644 mindi.8 $local/share/man/man8
|
---|
53 | install -m 644 CHANGES COPYING README README.busybox README.ia64 README.pxe TODO INSTALL $local/share/doc/mindi-$MINDIVER
|
---|
54 |
|
---|
55 | ARCH=`/bin/arch`
|
---|
56 | echo $ARCH | grep -x "i[0-9]86" &> /dev/null && ARCH=i386
|
---|
57 | # For the moment, we don't build specific x86_64 busybox binaries
|
---|
58 | echo $ARCH | grep -x "x86_64" &> /dev/null && ARCH=i386
|
---|
59 | export ARCH
|
---|
60 |
|
---|
61 | # Managing busybox
|
---|
62 | if [ -f $local/lib/mindi/rootfs/bin/busybox-$ARCH ]; then
|
---|
63 | echo "Installing busybox ..."
|
---|
64 | install -s -m 755 $local/lib/mindi/rootfs/bin/busybox-$ARCH $local/lib/mindi/rootfs/bin/busybox
|
---|
65 | else
|
---|
66 | echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
|
---|
67 | fi
|
---|
68 | if [ "$ARCH" = "i386" ] ; then
|
---|
69 | if [ -f $local/lib/mindi/rootfs/bin/busybox-$ARCH.net ]; then
|
---|
70 | echo "Installing busybox.net ..."
|
---|
71 | install -s -m 755 $local/lib/mindi/rootfs/bin/busybox-$ARCH.net $local/lib/mindi/rootfs/bin/busybox.net
|
---|
72 | else
|
---|
73 | echo "WARNING: no busybox.net found, mindi will not work on this arch ($ARCH) with network"
|
---|
74 | fi
|
---|
75 | fi
|
---|
76 | # Remove left busybox
|
---|
77 | rm -f $local/lib/mindi/rootfs/bin/busybox-*
|
---|
78 |
|
---|
79 | # Managing parted2fdisk
|
---|
80 | if [ "$ARCH" = "ia64" ] ; then
|
---|
81 | (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
|
---|
82 | make -f Makefile.parted2fdisk DEST=$local/lib/mindi install
|
---|
83 | if [ -f $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
|
---|
84 | echo "Installing parted2fdisk ..."
|
---|
85 | install -s -m 755 $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/lib/mindi/rootfs/sbin/parted2fdisk
|
---|
86 | install -s -m 755 $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
|
---|
87 | else
|
---|
88 | echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
|
---|
89 | fi
|
---|
90 | else
|
---|
91 | # FHS requires fdisk under /sbin
|
---|
92 | (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
|
---|
93 | echo "Symlinking fdisk to parted2fdisk"
|
---|
94 | ( cd $local/lib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
|
---|
95 | fi
|
---|
96 | # Remove left parted2fdisk
|
---|
97 | rm -f $local/lib/mindi/rootfs/sbin/parted2fdisk-*
|
---|
98 |
|
---|
99 | if [ "$RPMBUILDMINDI" != "true" ]; then
|
---|
100 | chown -R root:root $local/lib/mindi $conf/mindi $conf $local/share/doc/mindi-$MINDIVER
|
---|
101 | chown root:root $local/sbin/mindi $local/share/man/man8/mindi.8 $local/sbin/analyze-my-lvm $local/sbin/parted2fdisk.pl
|
---|
102 | if [ "$ARCH" = "ia64" ] ; then
|
---|
103 | chown root:root $local/sbin/parted2fdisk
|
---|
104 | fi
|
---|
105 | fi
|
---|
106 |
|
---|
107 | exit 0
|
---|