[1467] | 1 | README for mondo/mindi usage with tools to backup Hardware configuration
|
---|
| 2 |
|
---|
| 3 | Some Hardware Manufacturers such as HP provide tools to store the Hardware configuration of their systems, such as the BIOS setup, the RAID setup, ...
|
---|
| 4 |
|
---|
| 5 | Mindi has a script able to store the Hardware configuration and those parameters may be restored before launching mondorestore during the boot phase computed by mindi, in order to re-setup the machine as the original one.
|
---|
| 6 |
|
---|
| 7 | For the moment, only HP Proliant systems are supported. If you have tools to allow support for other type of machines, feel free to contribute patches to that script.
|
---|
| 8 |
|
---|
| 9 | If you have a Proliant system you first need to get the Smart Start Scripting Toolkit. Due to licenses issues, mindi cannot provide those tools itself. You need to get them from http://www.hp.com/servers/sstoolkit
|
---|
| 10 |
|
---|
| 11 | Mindi expects to find those tools under /usr/local/bin as described in the deplist.d/proliant.conf configuration file. Here are the steps to set it up correctly:
|
---|
| 12 |
|
---|
[1770] | 13 | Older URL:
|
---|
| 14 | wget ftp://ftp.compaq.com/pub/softlib2/software1/pubsw-linux/p308169895/v40154/ss-scripting-toolkit-linux-1.70.tar.gz
|
---|
| 15 |
|
---|
[1467] | 16 | cd /tmp
|
---|
[1770] | 17 | wget ftp://ftp.hp.com/pub/softlib2/software1/pubsw-linux/p308169895/v43548/ss-scripting-toolkit-linux-1.81.tar.gz
|
---|
[1467] | 18 | mkdir ssstk
|
---|
| 19 | cd ssstk
|
---|
[1770] | 20 | tar xvfz ../ss-scripting-toolkit-linux-1.81.tar.gz
|
---|
[1467] | 21 | cp -a utilities/hponcfg /usr/local/bin
|
---|
| 22 | cp -a utilities/conrep /usr/local/bin
|
---|
| 23 | cp -a utilities/conrep.xml /usr/local/bin
|
---|
| 24 | cp -a utilities/cpqacuxe/cpqacuxe /usr/local/bin
|
---|
| 25 | cp -a utilities/cpqacuxe/bld /usr/local/bin
|
---|
| 26 | mv /usr/local/bin/bld/*.so /usr/local/lib
|
---|
| 27 | echo /usr/local/lib >> /etc/ld.so.conf
|
---|
| 28 | ldconfig
|
---|
| 29 |
|
---|
[1842] | 30 | You're now ready to check your configuration by running:
|
---|
| 31 | mindi-bkphw /var/cache/mindi /etc/mindi
|
---|
| 32 | [First parameter is the directory where files will be generated,
|
---|
| 33 | Second parameter is the directory of the file proliant.files is located]
|
---|
[1469] | 34 |
|
---|
[1842] | 35 | For these tools to work you may have to install additional packages such as hpasm and hprsm from the HP Web site, as well as some libstdc++ compatibility packages (compat-libstdc++-33 and compat-libstdc++-296 on RHEL 5 e.g.)
|
---|
[1469] | 36 |
|
---|
[1467] | 37 | In order to have a working hponcfg binary you also need to install the hprsm/hpasm packages from HP Web site. Refer to http://welcome.hp.com/country/us/en/support.html?pageDisplay=drivers
|
---|
| 38 |
|
---|
| 39 | 2007-05-30 Initial file
|
---|
[1770] | 40 | >>>>>>> .fusion-droit.r1769
|
---|