[3182] | 1 | #!/usr/bin/perl -w
|
---|
| 2 | #
|
---|
| 3 | # $Id$
|
---|
| 4 | #
|
---|
| 5 | # Gives the right driver to use for HP Smart Array Controllers for the corresponding Linux distribution
|
---|
| 6 | # Vased on the HP document hpsa migration at
|
---|
| 7 | #
|
---|
| 8 | use strict;
|
---|
| 9 |
|
---|
| 10 | my $drv = {
|
---|
| 11 | "P420i"
|
---|
| 12 | }
|
---|
| 13 |
|
---|
| 14 | # Handling Configuration files
|
---|
| 15 | my $tool = "";
|
---|
| 16 | my $ret = 0;
|
---|
| 17 | my $productname = undef;
|
---|
| 18 |
|
---|
| 19 | die "You need dmidecode for Hardware support\n" if (! -x "/usr/sbin/dmidecode");
|
---|
| 20 |
|
---|
| 21 | mkdir $bkpdir,0755 if (! -d $bkpdir) ;
|
---|
| 22 | open(SYSTEM,"/usr/sbin/dmidecode -s 'system-product-name' 2> /dev/null |") || die "You need /usr/sbin/dmidecode for mindi hardware support";
|
---|
| 23 | while (<SYSTEM>) {
|
---|
| 24 | next if (/^#/);
|
---|
| 25 | $productname = $_;
|
---|
| 26 | chomp($productname);
|
---|
| 27 | }
|
---|
| 28 | close(SYSTEM);
|
---|
| 29 |
|
---|
| 30 | die "INFO: No product name found for Hardware support\n" if (not defined $productname);
|
---|
| 31 |
|
---|
| 32 | if ($productname =~ /proliant/i) {
|
---|
| 33 | print "Detected a $productname. Nice. Continue to support my job :-)\n";
|
---|
| 34 | print "Activating ProLiant support for mindi\n";
|
---|
| 35 | print "You can install SDR packages to benefit from mindi's enhanced ProLiant support\n";
|
---|
[3530] | 36 | print "Get them from http://downloads.linux.hpe.com/SDR/\n";
|
---|
[3182] | 37 | open(PROLIANT,"$confdir/deplist.d/ProLiant.conf") || die "Unable to open $confdir/deplist.d/ProLiant.conf";
|
---|
| 38 | # generate a list of what need to be put on the backup media
|
---|
| 39 | open(TOOLS,"> $bkpdir/../tools.files") || die "Unable to open $bkpdir/../tools.files";
|
---|
| 40 | # generate a script that will be launched at rstore time to perform the HW setup
|
---|
| 41 | open(SCRIPT,"> $bkpdir/../mindi-rsthw") || die "Unable to open $bkpdir/../mindi-rsthw";
|
---|
| 42 | print SCRIPT << 'EOF';
|
---|
| 43 | #!/bin/bash
|
---|
| 44 | #
|
---|
| 45 | # Script generated by mindi
|
---|
| 46 | #
|
---|
| 47 | # This script will restore potentially your HW configuration
|
---|
| 48 | # on your system before partioning occurs.
|
---|
| 49 | #
|
---|
| 50 | # You may want to reboot after that step if you think that
|
---|
| 51 | # resetting BIOS parameters to the value restored
|
---|
| 52 | # may have an impact on your restoration process or if
|
---|
| 53 | # you want to benefit from any firmware update that could have happened.
|
---|
| 54 | #
|
---|
| 55 | EOF
|
---|
| 56 | while($tool = <PROLIANT>) {
|
---|
| 57 | my $hasfound = 0;
|
---|
| 58 | next if ($tool =~ /^#/);
|
---|
| 59 | chomp($tool);
|
---|
| 60 | # skip non-executable/exising binaries
|
---|
| 61 | if (! (-x $tool)) {
|
---|
| 62 | next;
|
---|
| 63 | } else {
|
---|
| 64 | print "Found $tool, activating enhanced HP ProLiant support in mindi\n";
|
---|
| 65 | print TOOLS "$tool\n";
|
---|
| 66 | }
|
---|
| 67 | if ($tool =~ /\/conrep$/) {
|
---|
| 68 | my $xmlf = "/opt/hp/hp-scripting-tools/etc/conrep.xml";
|
---|
| 69 | # From the package
|
---|
| 70 | if (-f $xmlf) {
|
---|
| 71 | $ret = system("$tool -s -x $xmlf -f$bkpdir/conrep.dat");
|
---|
| 72 | # From the SSSTK
|
---|
| 73 | } else {
|
---|
| 74 | $xmlf = "/usr/share/conrep/conrep.xml";
|
---|
| 75 | if (-f $xmlf) {
|
---|
| 76 | $ret = system("$tool -s -x $xmlf -f$bkpdir/conrep.dat");
|
---|
| 77 | } else {
|
---|
| 78 | next;
|
---|
| 79 | }
|
---|
| 80 | }
|
---|
| 81 | print SCRIPT "$tool -l -f$locbkpdir/conrep.dat\n";
|
---|
| 82 | print TOOLS "$xmlf\n";
|
---|
| 83 | }
|
---|
| 84 | if ($tool =~ /\/hp-rcu$/) {
|
---|
| 85 | $ret = system("$tool -s -f$bkpdir/conrep.dat");
|
---|
| 86 | print SCRIPT "$tool -l -f$locbkpdir/conrep.dat\n";
|
---|
| 87 | }
|
---|
| 88 | if ($tool =~ /\/hpacuscripting$/) {
|
---|
| 89 | $hasfound = 1;
|
---|
| 90 | my $dir=basename($tool);
|
---|
| 91 | # Just backup internal info for a DR
|
---|
| 92 | $ret = system("$tool -c $bkpdir/hpacuscripting.dat -internal");
|
---|
| 93 | # We could want to reset it before.
|
---|
| 94 | print SCRIPT "# $tool -reset -i $locbkpdir/hpacusripting.dat\n";
|
---|
| 95 | print SCRIPT "$tool -i $locbkpdir/hpacusripting.dat\n";
|
---|
| 96 | }
|
---|
| 97 | if ($tool =~ /\/hponcfg$/) {
|
---|
| 98 | $ret = system("$tool -a -w $bkpdir/hponcfg.dat");
|
---|
| 99 | print SCRIPT "$tool -f $locbkpdir/hponcfg.dat\n";
|
---|
| 100 | }
|
---|
| 101 | if ($tool =~ /\.scexe$/) {
|
---|
| 102 | print "Found $tool, that firmware will be applied at restore time on your HP ProLiant\n";
|
---|
| 103 | print SCRIPT "./$tool -s\n";
|
---|
| 104 | }
|
---|
| 105 | if ($tool =~ /\/hp-fm/) {
|
---|
| 106 | print "Found $tool, firmware will be upgraded at restore time on your HP ProLiant\n";
|
---|
| 107 | print SCRIPT "./$tool upgrade\n";
|
---|
| 108 | }
|
---|
| 109 | # Kept for compatibility with older version of tools
|
---|
| 110 | if (($tool =~ /\/hpacucli$/) && ($hasfound == 0)) {
|
---|
| 111 | my $dir=basename($tool);
|
---|
| 112 | $ret = system("$tool -c $bkpdir/hpacucli.dat");
|
---|
| 113 | print SCRIPT "$tool -i $locbkpdir/hpacucli.dat\n";
|
---|
| 114 | }
|
---|
| 115 | if ($ret != 0) {
|
---|
| 116 | print "$tool returned an error. Hardware support may not be complete\n";
|
---|
| 117 | }
|
---|
| 118 | }
|
---|
| 119 | close(PROLIANT);
|
---|
| 120 | close(TOOLS);
|
---|
| 121 | close(SCRIPT);
|
---|
| 122 | } else {
|
---|
| 123 | print "INFO: No Hardware optimized support for your product $productname\n";
|
---|
| 124 | print " You may ask your manufacturer to contribute to the mindi project\n for firmware Disaster Recovery support (harmless)\n";
|
---|
| 125 | }
|
---|
| 126 | rmdir $bkpdir if (-d $bkpdir) ;
|
---|