[1761] | 1 | README for mondo/mindi usage with tools to backup Hardware configuration
|
---|
| 2 |
|
---|
| 3 | Some Hardware Manufacturers such as HP provide tools to store the Hardware configuration of their systems, such as the BIOS setup, the RAID setup, ...
|
---|
| 4 |
|
---|
| 5 | Mindi has a script able to store the Hardware configuration and those parameters may be restored before launching mondorestore during the boot phase computed by mindi, in order to re-setup the machine as the original one.
|
---|
| 6 |
|
---|
| 7 | For the moment, only HP Proliant systems are supported. If you have tools to allow support for other type of machines, feel free to contribute patches to that script.
|
---|
| 8 |
|
---|
| 9 | If you have a Proliant system you first need to get the Smart Start Scripting Toolkit. Due to licenses issues, mindi cannot provide those tools itself. You need to get them from http://www.hp.com/servers/sstoolkit
|
---|
| 10 |
|
---|
| 11 | Mindi expects to find those tools under /usr/local/bin as described in the deplist.d/proliant.conf configuration file. Here are the steps to set it up correctly:
|
---|
| 12 |
|
---|
| 13 | Older URL:
|
---|
[2091] | 14 | wget ftp://ftp.hp.com/pub/softlib2/software1/pubsw-linux/p308169895/v40154/ss-scripting-toolkit-linux-1.70.tar.gz
|
---|
| 15 | wget ftp://ftp.hp.com/pub/softlib2/software1/pubsw-linux/p308169895/v43548/ss-scripting-toolkit-linux-1.81.tar.gz
|
---|
[1761] | 16 |
|
---|
| 17 | cd /tmp
|
---|
[2091] | 18 | wget ftp://ftp.hp.com/pub/softlib2/software1/pubsw-linux/p308169895/v44247/ss-scripting-toolkit-linux-1.90.tar.gz
|
---|
[1761] | 19 | mkdir ssstk
|
---|
| 20 | cd ssstk
|
---|
[2091] | 21 | tar xvfz ../ss-scripting-toolkit-linux-1.90.tar.gz
|
---|
[1761] | 22 | cp -a utilities/hponcfg /usr/local/bin
|
---|
| 23 | cp -a utilities/conrep /usr/local/bin
|
---|
| 24 | cp -a utilities/conrep.xml /usr/local/bin
|
---|
| 25 | cp -a utilities/cpqacuxe/cpqacuxe /usr/local/bin
|
---|
| 26 | cp -a utilities/cpqacuxe/bld /usr/local/bin
|
---|
| 27 | mv /usr/local/bin/bld/*.so /usr/local/lib
|
---|
| 28 | echo /usr/local/lib >> /etc/ld.so.conf
|
---|
| 29 | ldconfig
|
---|
| 30 |
|
---|
[1832] | 31 | You're now ready to check your configuration by running:
|
---|
| 32 | mindi-bkphw /var/cache/mindi /etc/mindi
|
---|
| 33 | [First parameter is the directory where files will be generated,
|
---|
| 34 | Second parameter is the directory of the file proliant.files is located]
|
---|
[1761] | 35 |
|
---|
[1832] | 36 | For these tools to work you may have to install additional packages such as hpasm and hprsm from the HP Web site, as well as some libstdc++ compatibility packages (compat-libstdc++-33 and compat-libstdc++-296 on RHEL 5 e.g.)
|
---|
| 37 |
|
---|
[1761] | 38 | In order to have a working hponcfg binary you also need to install the hprsm/hpasm packages from HP Web site. Refer to http://welcome.hp.com/country/us/en/support.html?pageDisplay=drivers
|
---|
| 39 |
|
---|
| 40 | 2007-05-30 Initial file
|
---|