source: MondoRescue/branches/2.2.5/mindi/install.sh @ 1708

Last change on this file since 1708 was 1708, checked in by Bruno Cornec, 12 years ago
  • Supress g_erase_tmpdir_and_scratchdir
  • Improve some log messages for USB support
  • Try to improve install in mindi to avoid issues with isolinux.cfg not installed vene if in the pkg :-(
  • Property svn:keywords set to Id
File size: 4.1 KB
Line 
1#!/bin/bash
2#
3# $Id: install.sh 1708 2007-10-27 14:42:34Z bruno $
4#
5
6if [ ! -f "mindi" ] ; then
7    echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
8    exit 1
9fi
10
11if [ "_$PREFIX" != "_" ]; then
12    local=${HEAD}$PREFIX
13    sublocal=$PREFIX
14    if [ "_$CONFDIR" != "_" ]; then
15        conf=${HEAD}$CONFDIR/mindi
16        subconf=$CONFDIR/mindi
17    else
18        echo "CONFDIR should be defined if PREFIX is defined"
19        exit -1
20    fi
21else
22    local=/usr/local
23    sublocal=$local
24    if [ -f /usr/sbin/mindi ]; then
25        echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
26    fi
27    conf=$local/etc/mindi
28    subconf=$conf
29    echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
30fi
31
32if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
33    local=/ramdisk/usr
34    sublocal=$local
35    conf=/ramdisk/etc
36    subconf=$conf
37    export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
38fi
39
40MINDIVER=PBVER
41MINDIREV=PBREV
42ARCH=`/bin/uname -m`
43echo "mindi ${MINDIVER}-r${MINDIREV} will be installed under $local"
44
45if [ _"$CACHEDIR" = _"" ]; then
46    CACHEDIR=$local/var/cache/mindi
47else
48    CACHEDIR=${HEAD}$CACHEDIR
49fi
50if [ _"$MANDIR" = _"" ]; then
51    MANDIR=$local/share/man/man8
52else
53    MANDIR=${HEAD}$MANDIR/man8
54fi
55if [ _"$DOCDIR" = _"" ]; then
56    DOCDIR=$local/share/doc/mindi-$MINDIVER
57else
58    DOCDIR=${HEAD}$DOCDIR/mindi-$MINDIVER
59fi
60if [ _"$LIBDIR" = _"" ]; then
61    echo $ARCH | grep -E '^i[0-9]86$' &> /dev/null && ARCH=i386 && locallib=$local/lib
62    echo $ARCH | grep -E '^x86_64$' &> /dev/null && locallib=$local/lib64
63    echo $ARCH | grep -E '^ia64$' &> /dev/null && locallib=$local/lib
64    sublocallib="$locallib/mindi"
65else
66    locallib=${HEAD}$LIBDIR
67    sublocallib="$LIBDIR/mindi"
68fi
69
70echo "Creating target directories ..."
71install -m 755 -d $conf $locallib/mindi $MANDIR $local/sbin $CACHEDIR # $DOCDIR
72
73echo "Copying files ..."
74install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $sublocallib
75install -m 644 deplist.txt $conf
76
77cp -af rootfs aux-tools $locallib/mindi
78chmod 755 $locallib/mindi/rootfs/sbin/*
79chmod 755 $locallib/mindi/aux-tools/sbin/*
80
81# Substitute variables for mindi
82sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$sublocal~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$subconf~" -e "s~^MINDI_LIB=LLL~MINDI_LIB=$sublocallib~" mindi > $local/sbin/mindi
83chmod 755 $local/sbin/mindi
84install -m 755 parted2fdisk.pl $local/sbin
85install -m 755 analyze-my-lvm $locallib/mindi
86
87install -m 644 mindi.8 $MANDIR
88#install -m 644 ChangeLog COPYING README README.busybox README.ia64 README.pxe TODO INSTALL svn.log $DOCDIR
89
90if [ "_$PREFIX" = "_" ] && [ ! -f $locallib/mindi/rootfs/bin/busybox ]; then
91        echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
92fi
93
94# Managing parted2fdisk
95if [ "$ARCH" = "ia64" ] ; then
96    (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
97    make -f Makefile.parted2fdisk DEST=$locallib/mindi install
98    if [ -f $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
99        echo "Installing parted2fdisk ..."
100        install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $locallib/mindi/rootfs/sbin/parted2fdisk
101        install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
102    else
103        echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
104    fi
105else
106    # FHS requires fdisk under /sbin
107    (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
108    echo "Symlinking fdisk to parted2fdisk"
109    ( cd $locallib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
110fi
111# Remove left parted2fdisk
112rm -f $locallib/mindi/rootfs/sbin/parted2fdisk-*
113
114if [ "$PKGBUILDMINDI" != "true" ]; then
115    chown -R root:root $locallib/mindi $conf # $DOCDIR
116    chown root:root $local/sbin/mindi $MANDIR/mindi.8 $locallib/mindi/analyze-my-lvm $local/sbin/parted2fdisk.pl
117    if [ "$ARCH" = "ia64" ] ; then
118        chown root:root $local/sbin/parted2fdisk
119    fi
120fi
121
122# Special case for SuSE family where doc is put elsewhere in the RPM
123# if [ -e /etc/SuSE-release ]; then
124    # rm -rf $DOCDIR
125# fi
126
127# Special case for Debian family where doc is put elsewhere in the DEB
128# if [ -e /etc/debian_version ]; then
129    # rm -rf $DOCDIR
130# fi
131
132exit 0
Note: See TracBrowser for help on using the repository browser.