[179] | 1 | #!/bin/bash
|
---|
[1] | 2 |
|
---|
| 3 | if [ ! -f "mindi" ] ; then
|
---|
| 4 | echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
|
---|
| 5 | exit 1
|
---|
| 6 | fi
|
---|
[179] | 7 |
|
---|
[184] | 8 | if [ "_$PREFIX" != "_" ]; then
|
---|
[235] | 9 | local=$PREFIX
|
---|
[179] | 10 | if [ -f /usr/local/sbin/mindi ]; then
|
---|
| 11 | echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
|
---|
| 12 | fi
|
---|
[235] | 13 | conf=$CONFDIR/mindi
|
---|
[185] | 14 | echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
|
---|
[179] | 15 | else
|
---|
| 16 | local=/usr/local
|
---|
| 17 | if [ -f /usr/sbin/mindi ]; then
|
---|
| 18 | echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
|
---|
| 19 | fi
|
---|
| 20 | conf=$local/etc/mindi
|
---|
[185] | 21 | echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
|
---|
[179] | 22 | fi
|
---|
| 23 |
|
---|
[1] | 24 | if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
|
---|
| 25 | local=/ramdisk/usr
|
---|
| 26 | export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
|
---|
| 27 | fi
|
---|
| 28 |
|
---|
[237] | 29 | MINDIVER=`cat VERSION`
|
---|
[243] | 30 | MINDIREV=`cat REVISION`
|
---|
| 31 | echo "mindi ${MINDIVER}-r${MINDIREV} will be installed under $local"
|
---|
[179] | 32 |
|
---|
[248] | 33 | DOCDIR=$local/share/doc/mindi-$MINDIVER
|
---|
| 34 | MANDIR=$local/share/man/man8
|
---|
[241] | 35 |
|
---|
[306] | 36 | ARCH=`/bin/arch`
|
---|
| 37 | echo $ARCH | grep -x "i[0-9]86" &> /dev/null && ARCH=i386 && locallib=$local/lib
|
---|
| 38 | # For the moment, we don't build specific x86_64 busybox binaries
|
---|
| 39 | echo $ARCH | grep -x "x86_64" &> /dev/null && ARCH=i386 && locallib=$local/lib64
|
---|
| 40 | export ARCH
|
---|
| 41 |
|
---|
[179] | 42 | echo "Creating target directories ..."
|
---|
[306] | 43 | install -m 755 -d $conf $locallib/mindi $MANDIR $local/sbin $DOCDIR
|
---|
[1] | 44 |
|
---|
[179] | 45 | echo "Copying files ..."
|
---|
[306] | 46 | install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $locallib/mindi
|
---|
[237] | 47 | install -m 644 deplist.txt $conf
|
---|
[235] | 48 |
|
---|
[311] | 49 | cp -af rootfs aux-tools $locallib/mindi
|
---|
[306] | 50 | chmod 755 $locallib/mindi/rootfs/bin/*
|
---|
| 51 | chmod 755 $locallib/mindi/rootfs/sbin/*
|
---|
| 52 | chmod 755 $locallib/mindi/aux-tools/sbin/*
|
---|
[1] | 53 |
|
---|
[179] | 54 | if [ "$RPMBUILDMINDI" = "true" ]; then
|
---|
[243] | 55 | sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
|
---|
[179] | 56 | else
|
---|
[243] | 57 | sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
|
---|
[179] | 58 | fi
|
---|
| 59 | chmod 755 $local/sbin/mindi
|
---|
[237] | 60 | install -m 755 analyze-my-lvm parted2fdisk.pl $local/sbin
|
---|
[179] | 61 |
|
---|
[248] | 62 | install -m 644 mindi.8 $MANDIR
|
---|
[315] | 63 | install -m 644 ChangeLog COPYING README README.busybox README.ia64 README.pxe TODO INSTALL svn.log $DOCDIR
|
---|
[179] | 64 |
|
---|
[235] | 65 | # Managing busybox
|
---|
[306] | 66 | if [ -f $locallib/mindi/rootfs/bin/busybox-$ARCH ]; then
|
---|
[179] | 67 | echo "Installing busybox ..."
|
---|
[306] | 68 | install -s -m 755 $locallib/mindi/rootfs/bin/busybox-$ARCH $locallib/mindi/rootfs/bin/busybox
|
---|
[179] | 69 | else
|
---|
| 70 | echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
|
---|
| 71 | fi
|
---|
[1] | 72 | if [ "$ARCH" = "i386" ] ; then
|
---|
[306] | 73 | if [ -f $locallib/mindi/rootfs/bin/busybox-$ARCH.net ]; then
|
---|
[179] | 74 | echo "Installing busybox.net ..."
|
---|
[306] | 75 | install -s -m 755 $locallib/mindi/rootfs/bin/busybox-$ARCH.net $locallib/mindi/rootfs/bin/busybox.net
|
---|
[179] | 76 | else
|
---|
| 77 | echo "WARNING: no busybox.net found, mindi will not work on this arch ($ARCH) with network"
|
---|
| 78 | fi
|
---|
[1] | 79 | fi
|
---|
[235] | 80 | # Remove left busybox
|
---|
[306] | 81 | rm -f $locallib/mindi/rootfs/bin/busybox-*
|
---|
[179] | 82 |
|
---|
[235] | 83 | # Managing parted2fdisk
|
---|
[1] | 84 | if [ "$ARCH" = "ia64" ] ; then
|
---|
[235] | 85 | (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
|
---|
[306] | 86 | make -f Makefile.parted2fdisk DEST=$locallib/mindi install
|
---|
| 87 | if [ -f $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
|
---|
[179] | 88 | echo "Installing parted2fdisk ..."
|
---|
[306] | 89 | install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $locallib/mindi/rootfs/sbin/parted2fdisk
|
---|
| 90 | install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
|
---|
[179] | 91 | else
|
---|
| 92 | echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
|
---|
| 93 | fi
|
---|
[1] | 94 | else
|
---|
[235] | 95 | # FHS requires fdisk under /sbin
|
---|
| 96 | (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
|
---|
[179] | 97 | echo "Symlinking fdisk to parted2fdisk"
|
---|
[306] | 98 | ( cd $locallib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
|
---|
[1] | 99 | fi
|
---|
[235] | 100 | # Remove left parted2fdisk
|
---|
[306] | 101 | rm -f $locallib/mindi/rootfs/sbin/parted2fdisk-*
|
---|
[179] | 102 |
|
---|
[237] | 103 | if [ "$RPMBUILDMINDI" != "true" ]; then
|
---|
[306] | 104 | chown -R root:root $locallib/mindi $conf $DOCDIR
|
---|
[248] | 105 | chown root:root $local/sbin/mindi $MANDIR/mindi.8 $local/sbin/analyze-my-lvm $local/sbin/parted2fdisk.pl
|
---|
[237] | 106 | if [ "$ARCH" = "ia64" ] ; then
|
---|
| 107 | chown root:root $local/sbin/parted2fdisk
|
---|
| 108 | fi
|
---|
| 109 | fi
|
---|
| 110 |
|
---|
[467] | 111 | # Special case for SuSE family where doc is put elsewhere in the RPM
|
---|
| 112 | if [ _"$dfam" = _"suse" ]; then
|
---|
[455] | 113 | rm -rf $DOCDIR
|
---|
| 114 | fi
|
---|
| 115 |
|
---|
[1] | 116 | exit 0
|
---|