source: MondoRescue/trunk/mindi/install.sh@ 914

Last change on this file since 914 was 914, checked in by Bruno Cornec, 17 years ago

merge -r902:913 $SVN_M/branches/stable

  • Property svn:keywords set to Id
File size: 4.3 KB
RevLine 
[181]1#!/bin/bash
[1]2
3if [ ! -f "mindi" ] ; then
4 echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
5 exit 1
6fi
[181]7
[186]8if [ "_$PREFIX" != "_" ]; then
[236]9 local=$PREFIX
[181]10 if [ -f /usr/local/sbin/mindi ]; then
11 echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
12 fi
[236]13 conf=$CONFDIR/mindi
[186]14 echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
[181]15else
16 local=/usr/local
17 if [ -f /usr/sbin/mindi ]; then
18 echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
19 fi
20 conf=$local/etc/mindi
[186]21 echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
[181]22fi
23
[1]24if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
25 local=/ramdisk/usr
26 export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
27fi
28
[238]29MINDIVER=`cat VERSION`
[244]30MINDIREV=`cat REVISION`
31echo "mindi ${MINDIVER}-r${MINDIREV} will be installed under $local"
[181]32
[250]33DOCDIR=$local/share/doc/mindi-$MINDIVER
34MANDIR=$local/share/man/man8
[244]35
[309]36ARCH=`/bin/arch`
[914]37echo $ARCH | grep -E '^i[0-9]86$' &> /dev/null && ARCH=i386 && locallib=$local/lib
38echo $ARCH | grep -E '^x86_64$' &> /dev/null && locallib=$local/lib64
39echo $ARCH | grep -E '^ia64$' &> /dev/null && locallib=$local/lib
[309]40export ARCH
41
[181]42echo "Creating target directories ..."
[461]43install -m 755 -d $conf $conf/deplist.d $locallib/mindi $MANDIR $local/sbin $DOCDIR
[1]44
[181]45echo "Copying files ..."
[309]46install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $locallib/mindi
[238]47install -m 644 deplist.txt $conf
[461]48install -m 644 distributions/conf/deplist.d/* $conf/deplist.d
49install -m 755 distributions/conf/mindi.conf $conf
[236]50
[317]51cp -af rootfs aux-tools $locallib/mindi
[309]52chmod 755 $locallib/mindi/rootfs/bin/*
53chmod 755 $locallib/mindi/rootfs/sbin/*
54chmod 755 $locallib/mindi/aux-tools/sbin/*
[461]55chmod 755 $conf/mindi.conf
[1]56
[904]57# Substirute variables for init
58perl -pi -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~ ; s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" $locallib/mindi/rootfs/sbin/init
59
60# Substirute variables for mindi
[181]61if [ "$RPMBUILDMINDI" = "true" ]; then
[244]62 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
[181]63else
[244]64 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
[181]65fi
66chmod 755 $local/sbin/mindi
[489]67install -m 755 parted2fdisk.pl $local/sbin
68install -m 755 analyze-my-lvm $locallib/mindi
[181]69
[250]70install -m 644 mindi.8 $MANDIR
[317]71install -m 644 ChangeLog COPYING README README.busybox README.ia64 README.pxe TODO INSTALL svn.log $DOCDIR
[181]72
[839]73if [ ! -f $locallib/mindi/rootfs/bin/busybox ]; then
[181]74 echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
75fi
76
[236]77# Managing parted2fdisk
[1]78if [ "$ARCH" = "ia64" ] ; then
[236]79 (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
[309]80 make -f Makefile.parted2fdisk DEST=$locallib/mindi install
81 if [ -f $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
[181]82 echo "Installing parted2fdisk ..."
[309]83 install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $locallib/mindi/rootfs/sbin/parted2fdisk
84 install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
[181]85 else
86 echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
87 fi
[1]88else
[236]89 # FHS requires fdisk under /sbin
90 (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
[181]91 echo "Symlinking fdisk to parted2fdisk"
[309]92 ( cd $locallib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
[1]93fi
[236]94# Remove left parted2fdisk
[309]95rm -f $locallib/mindi/rootfs/sbin/parted2fdisk-*
[181]96
[238]97if [ "$RPMBUILDMINDI" != "true" ]; then
[309]98 chown -R root:root $locallib/mindi $conf $DOCDIR
[489]99 chown root:root $local/sbin/mindi $MANDIR/mindi.8 $locallib/mindi/analyze-my-lvm $local/sbin/parted2fdisk.pl
[238]100 if [ "$ARCH" = "ia64" ] ; then
101 chown root:root $local/sbin/parted2fdisk
102 fi
103fi
104
[489]105# Special case for SuSE family where doc is put elsewhere in the RPM
[649]106if [ -e /etc/SuSE-release ]; then
[461]107 rm -rf $DOCDIR
108fi
109
[588]110# Special case for Debian family where doc is put elsewhere in the DEB
[649]111if [ -e /etc/debian_version ]; then
[588]112 rm -rf $DOCDIR
113fi
114
[1]115exit 0
Note: See TracBrowser for help on using the repository browser.