source: MondoRescue/branches/2.2.0/mindi/install.sh@ 2183

Last change on this file since 2183 was 834, checked in by Bruno Cornec, 18 years ago

All references to busybox in mindi have been cleaned up.

  • Property svn:keywords set to Id
File size: 4.0 KB
Line 
1#!/bin/bash
2
3if [ ! -f "mindi" ] ; then
4 echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
5 exit 1
6fi
7
8if [ "_$PREFIX" != "_" ]; then
9 local=$PREFIX
10 if [ -f /usr/local/sbin/mindi ]; then
11 echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
12 fi
13 conf=$CONFDIR/mindi
14 echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
15else
16 local=/usr/local
17 if [ -f /usr/sbin/mindi ]; then
18 echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
19 fi
20 conf=$local/etc/mindi
21 echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
22fi
23
24if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
25 local=/ramdisk/usr
26 export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
27fi
28
29MINDIVER=`cat VERSION`
30MINDIREV=`cat REVISION`
31echo "mindi ${MINDIVER}-r${MINDIREV} will be installed under $local"
32
33DOCDIR=$local/share/doc/mindi-$MINDIVER
34MANDIR=$local/share/man/man8
35
36ARCH=`/bin/arch`
37echo $ARCH | grep -x "i[0-9]86" &> /dev/null && ARCH=i386 && locallib=$local/lib
38echo $ARCH | grep -x "x86_64" &> /dev/null && locallib=$local/lib64
39echo $ARCH | grep -x "ia64" &> /dev/null && locallib=$local/lib
40export ARCH
41
42echo "Creating target directories ..."
43install -m 755 -d $conf $locallib/mindi $MANDIR $local/sbin $DOCDIR
44
45echo "Copying files ..."
46install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $locallib/mindi
47install -m 644 deplist.txt $conf
48
49cp -af rootfs aux-tools $locallib/mindi
50chmod 755 $locallib/mindi/rootfs/bin/*
51chmod 755 $locallib/mindi/rootfs/sbin/*
52chmod 755 $locallib/mindi/aux-tools/sbin/*
53
54if [ "$RPMBUILDMINDI" = "true" ]; then
55 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
56else
57 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
58fi
59chmod 755 $local/sbin/mindi
60install -m 755 parted2fdisk.pl $local/sbin
61install -m 755 analyze-my-lvm $locallib/mindi
62
63install -m 644 mindi.8 $MANDIR
64install -m 644 ChangeLog COPYING README README.busybox README.ia64 README.pxe TODO INSTALL svn.log $DOCDIR
65
66if [ ! -f $locallib/mindi/rootfs/bin/busybox ]; then
67 echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
68fi
69
70# Managing parted2fdisk
71if [ "$ARCH" = "ia64" ] ; then
72 (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
73 make -f Makefile.parted2fdisk DEST=$locallib/mindi install
74 if [ -f $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
75 echo "Installing parted2fdisk ..."
76 install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $locallib/mindi/rootfs/sbin/parted2fdisk
77 install -s -m 755 $locallib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
78 else
79 echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
80 fi
81else
82 # FHS requires fdisk under /sbin
83 (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
84 echo "Symlinking fdisk to parted2fdisk"
85 ( cd $locallib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
86fi
87# Remove left parted2fdisk
88rm -f $locallib/mindi/rootfs/sbin/parted2fdisk-*
89
90if [ "$RPMBUILDMINDI" != "true" ]; then
91 chown -R root:root $locallib/mindi $conf $DOCDIR
92 chown root:root $local/sbin/mindi $MANDIR/mindi.8 $locallib/mindi/analyze-my-lvm $local/sbin/parted2fdisk.pl
93 if [ "$ARCH" = "ia64" ] ; then
94 chown root:root $local/sbin/parted2fdisk
95 fi
96fi
97
98# Special case for SuSE family where doc is put elsewhere in the RPM
99if [ -e /etc/SuSE-release ]; then
100 rm -rf $DOCDIR
101fi
102
103# Special case for Debian family where doc is put elsewhere in the DEB
104if [ -e /etc/debian_version ]; then
105 rm -rf $DOCDIR
106fi
107
108exit 0