source: MondoRescue/branches/2.06/mindi/install.sh@ 276

Last change on this file since 276 was 267, checked in by bcornec, 18 years ago
  • CHANGES renamed also in install.sh now
  • Bug fix for chown in install.sh (JeffS)
  • Property svn:keywords set to Id
File size: 4.2 KB
Line 
1#!/bin/bash
2
3if [ ! -f "mindi" ] ; then
4 echo "Please 'cd' to the directory you have just untarred." >> /dev/stderr
5 exit 1
6fi
7
8if [ "_$PREFIX" != "_" ]; then
9 local=$PREFIX
10 if [ -f /usr/local/sbin/mindi ]; then
11 echo "WARNING: /usr/local/sbin/mindi exists. You should probably remove it !"
12 fi
13 conf=$CONFDIR/mindi
14 echo $PATH | grep /usr/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add /usr/sbin to your PATH."
15else
16 local=/usr/local
17 if [ -f /usr/sbin/mindi ]; then
18 echo "WARNING: /usr/sbin/mindi exists. You should probably remove the mindi package !"
19 fi
20 conf=$local/etc/mindi
21 echo $PATH | grep $local/sbin > /dev/null || echo "Warning - your PATH environmental variable is BROKEN. Please add $local/sbin to your PATH."
22fi
23
24if uname -a | grep Knoppix > /dev/null || [ -e "/ramdisk/usr" ] ; then
25 local=/ramdisk/usr
26 export PATH=/ramdisk/usr/sbin:/ramdisk/usr/bin:/$PATH
27fi
28
29MINDIVER=`cat VERSION`
30MINDIREV=`cat REVISION`
31echo "mindi ${MINDIVER}-r${MINDIREV} will be installed under $local"
32
33DOCDIR=$local/share/doc/mindi-$MINDIVER
34MANDIR=$local/share/man/man8
35
36echo "Creating target directories ..."
37install -m 755 -d $conf $local/lib/mindi $MANDIR $local/sbin $DOCDIR
38
39echo "Copying files ..."
40install -m 644 isolinux.cfg msg-txt sys-disk.raw.gz isolinux-H.cfg syslinux.cfg syslinux-H.cfg dev.tgz $local/lib/mindi
41install -m 644 deplist.txt $conf
42
43cp -af rootfs aux-tools Mindi $local/lib/mindi
44chmod 755 $local/lib/mindi/rootfs/bin/*
45chmod 755 $local/lib/mindi/rootfs/sbin/*
46chmod 755 $local/lib/mindi/aux-tools/sbin/*
47
48if [ "$RPMBUILDMINDI" = "true" ]; then
49 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=/usr~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=/etc/mindi~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
50else
51 sed -e "s~^MINDI_PREFIX=XXX~MINDI_PREFIX=$local~" -e "s~^MINDI_CONF=YYY~MINDI_CONF=$conf~" -e "s~^MINDI_VER=VVV~MINDI_VER=$MINDIVER~" -e "s~^MINDI_REV=RRR~MINDI_REV=$MINDIREV~" mindi > $local/sbin/mindi
52fi
53chmod 755 $local/sbin/mindi
54install -m 755 analyze-my-lvm parted2fdisk.pl $local/sbin
55
56install -m 644 mindi.8 $MANDIR
57install -m 644 ChangeLog COPYING README README.busybox README.ia64 README.pxe TODO INSTALL $DOCDIR
58
59ARCH=`/bin/arch`
60echo $ARCH | grep -x "i[0-9]86" &> /dev/null && ARCH=i386
61# For the moment, we don't build specific x86_64 busybox binaries
62echo $ARCH | grep -x "x86_64" &> /dev/null && ARCH=i386
63export ARCH
64
65# Managing busybox
66if [ -f $local/lib/mindi/rootfs/bin/busybox-$ARCH ]; then
67 echo "Installing busybox ..."
68 install -s -m 755 $local/lib/mindi/rootfs/bin/busybox-$ARCH $local/lib/mindi/rootfs/bin/busybox
69else
70 echo "WARNING: no busybox found, mindi will not work on this arch ($ARCH)"
71fi
72if [ "$ARCH" = "i386" ] ; then
73 if [ -f $local/lib/mindi/rootfs/bin/busybox-$ARCH.net ]; then
74 echo "Installing busybox.net ..."
75 install -s -m 755 $local/lib/mindi/rootfs/bin/busybox-$ARCH.net $local/lib/mindi/rootfs/bin/busybox.net
76 else
77 echo "WARNING: no busybox.net found, mindi will not work on this arch ($ARCH) with network"
78 fi
79fi
80# Remove left busybox
81rm -f $local/lib/mindi/rootfs/bin/busybox-*
82
83# Managing parted2fdisk
84if [ "$ARCH" = "ia64" ] ; then
85 (cd $local/sbin && ln -sf parted2fdisk.pl parted2fdisk)
86 make -f Makefile.parted2fdisk DEST=$local/lib/mindi install
87 if [ -f $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH ]; then
88 echo "Installing parted2fdisk ..."
89 install -s -m 755 $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/lib/mindi/rootfs/sbin/parted2fdisk
90 install -s -m 755 $local/lib/mindi/rootfs/sbin/parted2fdisk-$ARCH $local/sbin/parted2fdisk
91 else
92 echo "WARNING: no parted2fdisk found, mindi will not work on this arch ($ARCH)"
93 fi
94else
95 # FHS requires fdisk under /sbin
96 (cd $local/sbin && ln -sf /sbin/fdisk parted2fdisk)
97 echo "Symlinking fdisk to parted2fdisk"
98 ( cd $local/lib/mindi/rootfs/sbin && ln -sf fdisk parted2fdisk)
99fi
100# Remove left parted2fdisk
101rm -f $local/lib/mindi/rootfs/sbin/parted2fdisk-*
102
103if [ "$RPMBUILDMINDI" != "true" ]; then
104 chown -R root:root $local/lib/mindi $conf $DOCDIR
105 chown root:root $local/sbin/mindi $MANDIR/mindi.8 $local/sbin/analyze-my-lvm $local/sbin/parted2fdisk.pl
106 if [ "$ARCH" = "ia64" ] ; then
107 chown root:root $local/sbin/parted2fdisk
108 fi
109fi
110
111exit 0
Note: See TracBrowser for help on using the repository browser.